
The Minuteman® is a minimally invasive, interspinous-interlaminar fusion device intended for the fixation and stabilization of the thoracic, lumbar, and sacral spine while awaiting bony fusion to occur. The Minuteman® is designed for attachment to the posterior non-cervical spine at the spinous processes through its bilateral locking plates, and it is intended for use with bone graft material placed within the device. It provides immobilization and stabilization of the spinal segments. The core threaded post allows for optimal placement and a wide range of sizes allows for enhanced anatomical fit. The Minuteman® is delivered sterile and individually packed.
Features & Benefits

Full Control Over Implant Wings
______
Allows the user to deploy and retract the wings intraoperatively
Single Piece Implant Body
______
Minimizes device profile without the need to remove a portion of the threaded body
60° Wing Angle
______
Designed to provide improved biomechanical stability in response to axial rotation and lateral bending loading
Lower Profile Compared to Minuteman® G3-R
______
Allows the implants to be inserted down a smaller diameter sleeve from the MIS Lateral approach
Hydroxyapatite Coated Fixation Hex Nut
______
A substance that helps promote bone on-growth and fusion. Maximizes bone-implant contact area to promote stability and fusion.
Safer Zone
______
Lateral MIS approach is above the facet joints, avoiding the neural and vascular structures
Minimally Invasive
______
Alternative to traditional pedicle screws and other spinous process plates
Lateral MIS Approach
______
Eliminates the dissection of the healthy tissue (neural monitoring is not required)
Ligament Preservation
______
Of the supraspinous ligament helps maintain stabilization of the spine
Large Graft Window
______
Allows easy placement of bone graft material to facilitate a posterior fusion
Threaded Body
______
Allows the implant to thread between the spinous processes in a controlled fashion
5 Anatomical Sizes
______
(8mm, 10mm, 12mm, 14mm, and 16mm) to accommodate variations in patient anatomy
Sterile Packed
______
Promotes patient safety and compliance at hospitals

Low Profile
______
With 12mm removable portion of the implant body
Reversible Auto-Lock
______
Enables the device to variably tighten without compromising fixation
Hydroxyapatite Coating
______
A substance that helps promote bone on-growth and fusion.
Safer Zone
______
Lateral MIS approach is above the facet joints, avoiding the neural and vascular structures
Minimally Invasive
______
Alternative to traditional pedicle screws and other spinous process plates
Lateral MIS Approach
______
Eliminates the dissection of the healthy tissue (neural monitoring is not required)
Ligament Preservation
______
Of the supraspinous ligament helps maintain stabilization of the spine
Large Graft Window
______
Allows easy placement of bone graft material to facilitate a posterior fusion
Threaded Body
______
Allows the implant to thread between the spinous processes in a controlled fashion
5 Anatomical Sizes
______
(8mm, 10mm, 12mm, 14mm, and 16mm) to accommodate variations in patient anatomy
Sterile Packed
______
Promotes patient safety and compliance at hospitals
Minuteman® Lateral Fusion
Indications for Use
The Minuteman® MIS Fusion Plate is a posterior, non-pedicle supplemental fixation device, intended for use at a single level in the non-cervical spine (T1-S1). It is intended for use with bone graft material and is not intended for stand-alone use. The Minuteman® MIS Fusion Plate may be implanted via a minimally invasive lateral (L1-S1) approach. It is intended for plate fixation/attachment to spinous processes for the purpose of achieving supplemental fusion in the following conditions: Lumbar Spinal Stenosis, Degenerative Disc Disease, Spondylolisthesis, Trauma, and Tumor.